> For the complete documentation index, see [llms.txt](https://docs.themeatstick.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.themeatstick.com/your-product/blow/troubleshooting.md).

# Troubleshooting

## The cooker won't reach my target

1. **Is the damper open?** It arrives closed, and closed means no air reaches the fire.
2. **Are all the other intakes taped shut?** And is the top vent open at least a pencil-width?
3. **Is there enough lit fuel?**
4. **Is the probe out of the Blow's airflow?** Air straight from the fan makes it read low.
5. Still won't climb? **Lift the damper out** for maximum airflow. Keep it with the Blow: you need it back on to shut the cook down.
6. **Check the power source.** Below 5 V / 2 A, the fan may not reach full speed.

## The cooker runs too hot, or overshoots

* **Look for air leaks** around the mount, the gasket, or an unsealed vent. If the cooker climbs with the fan stopped, air is getting in somewhere else.
* **Close the top vent down** a little. Wide open, it lets the fire draw air without the fan.
* **Light less charcoal** next time. Kamados in particular are slow to come back down.
* **Check the gasket is fitted** and sealing.

## The temperature reading looks wrong

Check **where the probe is clipped**: grate level, over indirect heat, not above the coals. Settled coals throw as much heat as open flame, and a probe in the rising heat reads high. Keep the tip off metal and out of the fan's airflow.

The grate reading will differ from your cooker's lid gauge. That's expected, not a fault. See [Where to put the Wired Ambient Probe](https://docs.themeatstick.com/your-product/blow/running-the-blow#where-to-put-the-wired-ambient-probe).

## The pit shows no temperature

During a Blow cook, the Wired Ambient Probe plugs into the **Blow**, not the Hub. Check it's in the Blow's probe port, and that the hub cable is connected at both ends.

## The Blow won't run

* Try a different USB charger or power bank. A power bank must be charged and switched on.
* Check the hub cable is pushed fully into the Blow and the Forge Hub.
* Check your Forge Hub is online in the app.
* **If the fan doesn't spin at all, check the pit temperature in the app.** The fan doesn't start until the pit reads about 86°F (30°C), so get your coals lit first. If the pit is already at or above target, that's normal: it starts again when the temperature drops.

## The app doesn't find my Blow

* Check the hub cable at both ends. It goes into the small round ambient port on the Forge Hub, not the USB-C port.
* Make sure your Forge Hub is set up and online in the app.
* **Can't see the Blow?** Update your V Forge WiFi Hub to the latest firmware.

## The fan stopped partway through a long cook, on a power bank

Many power banks switch themselves off when the draw is low, and the Blow runs gently once it's holding temperature. Use a wall charger for long cooks. See [Powering your Blow](https://docs.themeatstick.com/your-product/blow/power).

## The fan is noisy or vibrating

Check for ash or debris in the intake or outlet, and make sure the Blow is mounted firmly with the spring clip.

## My Stick keeps losing connection

Keep the Forge Hub within about 6 feet of your Stick. A closed metal cooker cuts Bluetooth range well below the spec-sheet figure. See [Connection drops or "no signal"](https://docs.themeatstick.com/fix-a-problem/connection-drops-or-no-signal).

## Still stuck?

[Fill out a ticket in the app](https://tms.fyi/help) or email <support@themeatstick.com>.