# Running a cook with the Blow

## Before you light

* **Damper open.** It's on the fan's air intake. Closed, no air reaches the fire.
* **Other vents sealed**, top vent at about a pencil-width.
* **Probe in the Blow**, tip clipped at grate level over indirect heat.
* **Blow and Forge Hub both powered.**

Then light a **small** amount of charcoal, close the lid, and set your target pit temperature in the app. The Blow brings the cooker up to target and holds it there.

## Where to put the Wired Ambient Probe

The Blow can only hold the temperature the probe reads, so placement matters.

* **Grate level, over indirect heat:** in the part of the cooker where your food sits, to one side of the coal bed.
* **Not above the coals.** Settled coals throw just as much heat as open flame, so keep the tip away from the fuel even when nothing is visibly burning. A probe in the rising heat reads the plume, not the cooker: it runs high, and the Blow cuts air your food needed.
* **Off metal, and out of the Blow's airflow.** Air straight from the fan makes the probe read low.

<figure><img src="https://480337956-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2F-Mg4Jg9fo_8jMW0As7z7%2Fuploads%2FdzYdjwaZnNSc8oHF1poX%2Fblow-probe-placement.png?alt=media" alt="Probe tip at grate level beside the coals"><figcaption><p>Probe tip at grate level, to the side of the coals, not above them.</p></figcaption></figure>

The reading at your grate will differ from your cooker's built-in lid gauge. That's expected: the grate is where your food cooks.

## What normal looks like

* **Near your target, the fan works in cycles.** At low targets it pulses on and off every few seconds. At higher targets it runs for a while, then rests for minutes. Either way, it's trimming the fire to hold temperature. That's normal, not a fault.
* **If the fan stops and the app shows the pit at or above target, that's normal.** The Blow cuts the fan to zero on purpose so the pit can settle, and starts it again when the temperature drops. The fan also waits to start until the pit reads about 86°F (30°C), so get your coals lit first. If the fan stops partway through a cook with the pit below target, check the app for an alert.
* **Charcoal is not an oven.** Expect the pit to drift a little around your target rather than sit exactly on it.

Watch your pit and food temperatures live in the app. Your meat cook and the Blow run side by side: your Stick alerts you when the food is done while the Blow keeps holding the fire.

## Opening the lid

Lifting the lid drops the pit temperature and lets extra air reach the fire. The Blow notices and **pauses its fan** for about two minutes, then picks back up on its own.

* **Keep lid-open time short.**
* **On a kamado**, briefly close the top vent while the lid is open. The ceramic holds heat and can overshoot. If it does, expect 30 to 60 minutes to recover.

## Adding fuel

If the pit starts dropping with the fan running, your fire is likely running low. Add charcoal, then check the damper and top vent are open.

## Shutting down

Stopping the Blow is a short routine, not an off switch:

1. **Stop the Blow in the app.** Ending your meat cook doesn't stop the Blow: the fire and the food are controlled separately.
2. **Close the Blow's damper.** This is what shuts off air to the fire.
3. **Close the top vent** and any other vents.
4. **Let everything cool** before you detach the Blow.

Then see [Care, storage and weather](https://docs.themeatstick.com/your-product/blow/care-and-weather).